concrete repair products - Concrete repair Fast setting non shrink grout repair concrete

SEARCH SITE

PRODUCT GUIDE

Click here to find the best product for your application

PROJECT REPORTS


Quick Setting Concrete Repair Mix

Rapid Set® Eisenwall® — SPECIFICATION
Premium Cement for Exterior Plastering
 
SECTION 09200
 

Rapid Set® EISENWALL®
PREMIUM STUCCO SYSTEM
(CONVENTIONAL APPLICATION)

  NOTE TO SPECIFIER

THE FOLLOWING SPECIFICATION HAS BEEN PREPARED TO ASSIST ARCHITECTS AND DESIGN PROFESSIONALS IN THE PREPARATION OF PROJECT MASTER SPECIFICATIONS. THIS SPECIFICATION IS BASED UPON THE MASTERFORMAT (1995) DEVELOPED BY THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI), AND CAN BE INCORPORATED INTO MOST MASTER SPECIFICATIONS WITH MINIMAL EDITING.

EDIT AND MODIFY AS NECESARY TO SUIT THE PROJECT MASTER SPECIFICATION. DELETE ANY ITEMS THAT ARE NOT APPLICABLE AND VERIFY THAT REFERENCED SECTION NUMBERS AND TITLES ARE CORRECT. CONTACT Rapid Set®Ò PRODUCTS FOR ANY ADDITIONAL INFORMATION OR SPECIFICATIONS ASSISTANCE, WRITING, AND ADAPTATION.
    PART I - GENERAL
PART II - PRODUCTS
PART III - EXECUTION
 

____________________________________

 

PART I - GENERAL

SUMMARY:
Provide all labor, materials, equipment and accessories necessary for compliance with this section and installation of Rapid Set® EISENWALL® Premium Stucco System.

RELATED SECTIONS:
 
  • 03300 - Cast-in-Place Concrete
  • 04200 - Unit Masonry
  • 05400 - Light gauge cold-formed steel framing
  • 06100 - Rough Carpentry: Wood framed construction
  • 06160 - Sheathing
 
REFERENCE STANDARDS:
 
  • UBC - Uniform Building Code
  • ICBO-ER 5102
  • ASTM C1063 - Installation of Lathing and Furring for portland cement Based Plaster
  • ASTM C847 - Standard Specification for Metal Lath
  • Plaster and Drywall Systems Manual, Third Edition
 
DESCRIPTION:
The Rapid Set® EISENWALL® Premium Stucco System consists of Rapid Set® EISENWALL® Cement mixed with a high quality graded plaster sand, reinforced with metal lath. The system is installed on exterior walls of wood, steel, masonry, or concrete construction.
 
SUBMITTALS:
Reference Section 01300 - Submittal Procedures, submit the following items:
 
  • All product data sheets, specifications, and details that pertain to the project, for architect approval.
  • Manufacturer's certificate of Approved Applicator status, or letter from manufacturer stating temporary approval pending jobsite training and certification.
  • Manufacturer's Application Guidelines.
  • Samples: Samples of an adequate size and number as specified by the architect to show color and texture of finish coat. Final applied colors and textures shall match Architect's approved samples. Samples shall be retained on site throughout the construction process.
 
QUALITY ASSURANCE:
  • System components shall be manufactured or approved for use by CTS Cement Manufacturing Corporation/Rapid Set® Products, and shall be distributed by the same or one of its authorized dealers.
  • Mock-Up: Upon request, provide a complete system sample panel of specified size using workmen, equipment, and techniques proposed for use on the project. Sample shall be reviewed for uniformity of depth and thickness, finish color and texture, and overall quality of construction. The panel shall remain on-site throughout the construction process. The approved panel shall become the standard of comparison for finished work for the project. Upon project completion, dispose of the sample panel appropriately.
  • Applicator/Contractor shall be experienced with the application of the EISENWALL® Premium Stucco System, and possess an Approved Applicator Certificate stating such. Alternatively, the applicator shall obtain a letter from the Manufacturer stating temporary approval and shall have a manufacturers' representative on-site for initial application.
 
DELIVERY, STORAGE, AND HANDLING:
  • Reference Section 01660 - Product Storage and Handling Requirements.
  • Materials shall be delivered in the manufacturers' original intact packaging labeled plainly with the manufacturers' name and brand, address and evaluation report number, identification of components, and weight of packaged mix.
  • Keep materials dry until used. Keep materials off the ground, under cover, and clear of damp walls or other damp surfaces. Store bulk sand in a well drained area on a clean, solid surface. Cover sand to prevent contamination with foreign matter.
 
PROJECT CONDITIONS:
  • Environmental Requirements: Maintain ambient and surface temperature between 40 and 100 degrees Fahrenheit during material application and curing periods.
  • Installation of the EISENWALL® Premium Stucco System shall be coordinated with all other trades and conditions so as to not impede overall general construction.
  • Sufficient manpower shall be provided to insure continuous application, timely finishing, and a product free of cold joints, scaffolding lines, variations in texture, etc.
  • Protect adjacent surfaces not specified to receive finishing, with drop cloths, waterproof paper, or other means to maintain them free of material splashes, overspray, water, or debris.
 
PART II - PRODUCTS MANUFACTURERS:
  • Acceptable basecoat material will be manufactured by the following:
    CTS Cement Manufacturing Corporation/Rapid Set® Products
    11065 Knott Avenue, Suite A
    Cypress, California 90630
    Ph: 800-929-3030 Fax: 714-379-8270
  • All lath, trims, accessories, and finishes shall be manufactured by specified manufacturer, or manufacturer approved by above [Rapid Set® Products].
  • Technical / Specifications Consultant:
    Ken Vallens
    Product Development Engineer:
    Rapid Set® Products
    Ph: 800-929-3030 x129
 
MATERIALS AND COMPONENTS:

Basecoat Components:
 
  • A. Cement shall be Rapid Set® EISENWALL® Cement; a rapid-setting, high early-strength, low shrinkage plastic cement, in 88lb. bags. Cement shall meet performance specifications below:
 
    • Minimum Compressive Strength (ASTM C-109)
      6 hr 400 psi
      24 hr 1500 psi
      3 day 2900 psi
      28 day 3500 psi
    • Set Time (ASTM C-403)
      Initial (minimum) 90 min.
      Final (maximum) 150 min.
    • Shrinkage (ASTM C-596 mod.)
      28 day maximum drying shrinkage -.019%
 
  • Sand must be clean and free from deleterious amounts of loam, clay, silt, soluble salts and organic matter. Sampling and testing must comply with ASTM C-144. Sand must be graded within the following limits:
 
    • Percent by weight retained on:
      US standard sieve Minimum (+2%) Maximum (+2%)
    No. 4
No. 8
No. 16
No. 30
No. 70
No. 95
----- 0
0 to 10
10 to 40
30 to 65
70 to 90
95 to 100
 
    • Water must be clean and free from deleterious amounts of silt and dissolved salts.
 
  • Lathing Materials: Per specification. For vertical surfaces.
 
    • Expanded self-furred metal lath fabricated from copper bearing steel, with weight of 3.4 pounds per square yard, and galvanized.
 
  • Accessories: all corner reinforcement / aid, casing beads, foundation weep screed, and control/expansion joints shall be galvanized steel and per drawings/specifications.
  • Fasteners: Comply with ASTM C-1063, or UBC, whichever is more stringent, for type and size of fastener required to rigidly secure materials in place.
PART III - EXECUTION PREPARATION:
  • All work shall be performed by skilled craftsmen, experienced in this type of work.
  • Examine substrate to insure that finished surfaces will be true, level, and plumb without requiring additional or uneven thickness of coatings. Verify that concrete and masonry are free of dust, loose particles, oil and other foreign matter which would adversely affect the bond of base coat. Notify the proper authority, in writing, of any discrepancies found in the substrate. Beginning of installation indicates acceptance of existing conditions.
  • Concrete/Masonry: Apply a bonding/sealing agent to concrete and masonry before application of base coat. Apply the bonding agent in accordance with manufacturers instructions.
INSTALLATION:

Install Rapid Set® EISENWALL® Premium Stucco System per manufacturers guidelines for application. Installation shall comply with UBC except as modified in ICBO ER-5102.
  • Weather Resistant Barrier: Install two layers of type D building paper complying with UBC 14-1. Building paper shall be applied horizontally, with the upper layer lapped over the lower layer a minimum of four inches. At vertical joints, a minimum lap of six inches is required. Stagger joint spacing of both layers of building paper. Application of the barrier must comply with section 1402.1 of the code.
  • Metal lath and accessories: Install per UBC and ASTM C-1063, whichever is more stringent.
 
  • Install trims prior to application of metal lath.
  • Metal lath shall be discontinuous under all control joints and expansion joints, providing free-floating panels.
  • Install corner reinforcement/aid at all exterior corners.
 
  • Mix and proportion Rapid Set® EISENWALL® Cement per manufacturers application guidelines.
  • Apply basecoat by hand trowelling or gun application, in one coat, to 3/4" thickness, using sufficient pressure and mechanical force, to embed metal lath, fill all spaces behind metal lath, and provide a mechanical key with metal lath.

*** Alternatively, basecoat can be applied in two coats, 3/8" thickness each, with the second coat being applied as soon as the first coat has attained sufficient rigidity to accept the mechanical force of application without damage.
  • Over concrete and masonry, apply basecoat in one coat to 1/2" thickness. Base coat shall be brought out to grounds, straightened to a true surface, and finished with sufficient texture to assure adequate bond with finish coat.
  • Moist cure basecoat for minimum 2 hours by providing light fog of clean, potable water as needed to maintain wet sheen.
  • Apply specified finish coat to 1/8" thickness, per manufacturers guidelines/instructions, as soon as basecoat is sufficiently hydrated. Basecoat may require light misting to ensure even suction. Apply finish coat evenly and consistently in order to achieve uniformity in color and texture.
  • Tolerances: Maximum variation from true flatness: 1/8" in 10ft.
  • Complete all work in the same plane and panel each day, Do NOT stop short, such as at expansion joints, etc.
ACCEPTANCE:
  • Upon completion, clean up overspray/spatters, remove all tools, equipment and unused materials. Remove all trash and protective masking, and clean all material from joints. Leave the work area in a clean, orderly state.

View Eisenwall Technical Bulletin